Page 1 of 1

Egt not working

Posted: Wed Mar 21, 2018 2:09 pm
by Maccas1
Hi Stewart I have used the m gauge settings you have posted but they don’t seem to be right as it is showing 1000 on the screen and I have only just started the ute

Can you help me please



Sent from my iPhone using Tapatalk

Re: Egt not working

Posted: Wed Mar 21, 2018 5:40 pm
by saeb
You have a pre DPF Ranger, the EGT sensor for that PID does not exist, hence 4.99volt = 1000 degrees =open circuit.

Re: Egt not working

Posted: Wed Mar 21, 2018 7:34 pm
by Maccas1
Ok thanks Stewart, is the only way to monitor egt is with a pyrometer in the exhaust bung. Post turbo? What’s the pyrometer in the exhaust manifold for?


Sent from my iPhone using Tapatalk

Re: Egt not working

Posted: Wed Mar 21, 2018 9:19 pm
by saeb
Maccas1 wrote: Wed Mar 21, 2018 7:34 pm Ok thanks Stewart, is the only way to monitor egt is with a pyrometer in the exhaust bung. Post turbo? What’s the pyrometer in the exhaust manifold for?


Sent from my iPhone using Tapatalk
At the moment yes.

I'm working on the correct PID for the Manifold and once sorted it will be added here viewtopic.php?f=19&t=58