Pre Turbo Temps

For vehicle specific questions please use the correct forum below.
User avatar
saeb
Site Admin
Site Admin
Posts: 4169
Joined: Wed May 17, 2017 8:50 pm
Location: Seaford VIC
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2015
Forscan Dongle Type: Ford VCM
Has thanked: 295 times
Been thanked: 1063 times

Can anyone that has monitored exhaust manifold outlet temp in the past give me an indication of what temps I'm looking for?

After spending 10 minutes I already have 10 new pids that are undocumented and it will make it a little easier to find EGT temp.

Possibility that I have found the pre turbo EGT anyway. slowly rising while idling 450 degree and start to go down when engine stopped.
Stewart

Ford PX2 Supercab 2015 Automatic
User avatar
saeb
Site Admin
Site Admin
Posts: 4169
Joined: Wed May 17, 2017 8:50 pm
Location: Seaford VIC
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2015
Forscan Dongle Type: Ford VCM
Has thanked: 295 times
Been thanked: 1063 times

Seems as though it may just be a different PID for engine coolant temp. Will keep and eye on it as it may be the same temp sensor or a different one. I had a feeling there were 2 on these engines.
Stewart

Ford PX2 Supercab 2015 Automatic
User avatar
saeb
Site Admin
Site Admin
Posts: 4169
Joined: Wed May 17, 2017 8:50 pm
Location: Seaford VIC
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2015
Forscan Dongle Type: Ford VCM
Has thanked: 295 times
Been thanked: 1063 times

Test and confirmed. It was just an undocumented PID for coolant.

So there are 2 PIDS for engine coolant in the PCM.
Stewart

Ford PX2 Supercab 2015 Automatic
Dieselman777
Donator
Donator
Posts: 10
Joined: Sun May 21, 2017 9:52 pm
Has thanked: 4 times
Been thanked: 2 times

Hello Stewart,

On my MY17 I am seeing anything from ambient temp on start up right up to 600 degrees during a long uphill run. Idle normally sits at 150-200 degrees

I can see pre and post cat temps on the MY17 using the OBDLink app and MX Link dongle
Meteor Grey MY17 PX2 XLT - New and unmolested for now
User avatar
saeb
Site Admin
Site Admin
Posts: 4169
Joined: Wed May 17, 2017 8:50 pm
Location: Seaford VIC
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2015
Forscan Dongle Type: Ford VCM
Has thanked: 295 times
Been thanked: 1063 times

Dieselman777 wrote: Tue Jun 13, 2017 7:36 pm Hello Stewart,

On my MY17 I am seeing anything from ambient temp on start up right up to 600 degrees during a long uphill run. Idle normally sits at 150-200 degrees

I can see pre and post cat temps on the MY17 using the OBDLink app and MX Link dongle
What PID are you using for Pre Turbo?
I assume you mean Pre/Post DPF?
Are you using the Post DPF PID I put up here?
Stewart

Ford PX2 Supercab 2015 Automatic
Dieselman777
Donator
Donator
Posts: 10
Joined: Sun May 21, 2017 9:52 pm
Has thanked: 4 times
Been thanked: 2 times

I am using the SAE PID in the OBDLink app "Exhaust gas temp bank 1, sensor 1"

I assume this would be pre-DPF/post turbo. I have been also getting different readings using "Catalyst temp (Bank 1 Sensor 1)" and "Catalyst temp (Bank 1 Sensor 1)"

I will see if I can get a log for you on the drive to Melb tomorrow morning


Ben
Meteor Grey MY17 PX2 XLT - New and unmolested for now
User avatar
saeb
Site Admin
Site Admin
Posts: 4169
Joined: Wed May 17, 2017 8:50 pm
Location: Seaford VIC
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2015
Forscan Dongle Type: Ford VCM
Has thanked: 295 times
Been thanked: 1063 times

I will PM you a PID post DPF. See how this compares to your other reading as we know its spot on.

I will look further into SAE PID and see what happens.
Stewart

Ford PX2 Supercab 2015 Automatic