Information: Following the announcement on October 23, 2023, this site has been archived as of July 1, 2024. For further details, visit this page.

ARB frontier tank install help, needed

For vehicle specific questions please use the correct forum below.
Brad66
Junior Member
Junior Member
Posts: 8
Joined: Mon May 11, 2020 2:26 pm
Location: Perth
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2016

Gday All, I am installing a frontier tank, the problem I have is that my float is sitting 5mm above the bench?
Not level as per instructions
So do I bend 12mm below bench?
Or 17mm below bench.
Factory tank was spot on for Dte /economy.
Thanks Brad
User avatar
RossPat
Moderator
Moderator
Posts: 1409
Joined: Wed Apr 04, 2018 9:33 pm
Location: Adelaide
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2018
Forscan Dongle Type: OBDlink MX Black Bluetooth
Has thanked: 32 times
Been thanked: 225 times

Hi.
Maybe have a read of the installation manual here.
https://www.saeb.net/viewtopic.php?f=31&t=1643
2018 XLT PX2 in Winning Blue
Brad66
Junior Member
Junior Member
Posts: 8
Joined: Mon May 11, 2020 2:26 pm
Location: Perth
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2016

Yep I have read the instructions.
The float is supposed to be level with the bench, it is not. it is 5mm higher.
The question is.....
How far below bench should I bend it.
Simple question I thought.
Obviously you did not understand
Brad66
Junior Member
Junior Member
Posts: 8
Joined: Mon May 11, 2020 2:26 pm
Location: Perth
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2016

Update.
Spoke to arb fitter.
His opinion was that the starting height of the float dose not matter,
And to bend it 15mm below bench top as per instructions.
Hope this helps someone else in the future.
User avatar
saeb
Site Admin
Site Admin
Posts: 4169
Joined: Wed May 17, 2017 8:50 pm
Location: Seaford VIC
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2015
Forscan Dongle Type: Ford VCM
Has thanked: 295 times
Been thanked: 1063 times

Bending to other specs will change things. It directly affects the fuel gauge level. No it will not affect DTE.

I cannot rememeber the specs on the install sheet but basically I bent 2mm more than the recommendations, so 17mm, nearly 5 years ago whichs gives me approx 5 litres left at 0 DTE. ARBs recommendations from memory leaves about 20 litres left at DTE.

Why it is not curretly level will make no difference to what ARBs specs state. Yours was most likely just wrong from the start.

NOTE.
Float level will only affect feul gauge.
Float level has no impact on DTE.
Stewart

Ford PX2 Supercab 2015 Automatic
Brad66
Junior Member
Junior Member
Posts: 8
Joined: Mon May 11, 2020 2:26 pm
Location: Perth
Model Of Vehicle: RANGER XLT PX2
Year Of Vehicle: 2016

Thanks Stewart for the info on not affecting DTE only gauge,
as the Dte is what I was concerned about.
I read your post and others regarding bending 2~3mm more, and that is what I have done.
So 17mm below bench.
I'll just monitor the gauge and if its too inaccurate I will drop tank and adjust arm again.
Hoping I won't have to.

Thanks again Brad